Problem connection to AP

  • July 7, 2015
  • 2 replies
  • 963 views
Posted on July 07, 2015 at 13:25

Hi.

I have a problem to connect the SPWF01SA1 with my Access Point. When the module try to connect restart before complete the Wifi scanning.

Does anybody can help me. my config, status, & capture file as attachment.

#spwf01sa1
    This topic has been closed for replies.

    2 replies

    Gerardo GALLUCCI
    ST Employee
    July 7, 2015
    Posted on July 07, 2015 at 14:01

    Hi Nick,

    first of all, please update the FW release to current 3.4.

    Then, your status dump shows a reset_reason equal to 0, meaning a ''power-on reset'' occurred. Are you using 3.3V as main power supply?

    Best regards

    jerry

    n2399
    n2399Author
    Associate
    July 7, 2015
    Posted on July 07, 2015 at 15:30

    Thanks for your reply.

    I update the firmware and i hope...

    The power is 3.3V .