Question

Reprogramming EVAL-SP1ML868 failure

  • June 5, 2017
  • 1 reply
  • 907 views
Posted on June 05, 2017 at 15:43

I am trying to reprogram EVAL-SP1ML868. I have read UM1889 and have the necessary software installed. I have fitted a shorting link to JP1. The 'Flash Loader Demonstrator' first screen 'Select communication port settings' I have set to the correct COM port (COM8 in this instance) and baud rate 115200. UM1889 does not tell me what to set Parity or Echo options to. I have tried every combination and only get error messages like 'No response from target...' or 'Unrecognized device...'.  What am I doing wrong?

The current firmware version is 1.03

#flash-loader-demonstrator #steval-sp1ml
This topic has been closed for replies.

1 reply

Michael Bailey
Associate
June 5, 2017
Posted on June 05, 2017 at 16:12

Having read more app notes I discover that Parity has to be set to Even. So I tried again and this time it worked!