Skip to main content
pagano.paganino
Associate III
November 18, 2016
Question

SPBTLE-RF FW 7.2c

  • November 18, 2016
  • 0 replies
  • 436 views
Posted on November 18, 2016 at 23:27

Hi,

i have a problem using SensorDemo_New of BlueNRG DK 2.0.2COPY_ENV_SENS_SERVICE_UUID(uuid);

ret = aci_gatt_add_serv(UUID_TYPE_128,  uuid, PRIMARY_SERVICE, 10, &envSensServHandle);i get ERR_UNSPECIFIED_ERRORif change max_attr_records to 7:

ret = aci_gatt_add_serv(UUID_TYPE_128,  uuid, PRIMARY_SERVICE, 7, &envSensServHandle);i get ERR_UNSPECIFIED_ERROR when call:

/* Humidity Characteristic */

  if(sensor_board){  

    COPY_HUMIDITY_CHAR_UUID(uuid); 

    ret =  aci_gatt_add_char(envSensServHandle, UUID_TYPE_128, uuid, 2, CHAR_PROP_READ, ATTR_PERMISSION_NONE, GATT_NOTIFY_READ_REQ_AND_WAIT_FOR_APPL_RESP,

                             16, 0, &humidityCharHandle);Any suggest?

Regards,

D.###############################################################################################Solved with correct max_attr_records (19) and correct char_value_len of the added gatt char.

Temperature char: char_value_len = 1

Pressure char: char_value_len = 2

Humiduty char: char_value_len = 2

Regards,

D.

This topic has been closed for replies.