Skip to main content
ikarus4ever
Visitor II
March 19, 2014
Solved

Bug in CR95HF development software

  • March 19, 2014
  • 1 reply
  • 958 views
Posted on March 19, 2014 at 13:44

First of all: I really like the software for DEMO-CR95HF-A.

But there is an issue with the scripting tool:

The command

CR95HF_ISO14443-A_SEND_APDU, 00A4040007a0000000030000

should be translated into

CR95HFDLL_SENDRECV, 0200A4040007a0000000030000CE2008

(or

0200A4040007a000000003000028

).

But the scripting tool translates it into

CR95HFDLL_SENDRECV, 0200A4040007a000000003000008

with the CRC missing!

Please fix this within version 1.7. Thank you!

#cr95hf #software #bug #demo-cr95hf-a #crc #cr95hf
This topic has been closed for replies.
Best answer by Anais GALLIGANI
Posted on March 19, 2014 at 17:15

Hello,

Thanks for the notice,

Your request will be taken into account

If you need a draft version with this modification we can send it by email

If not, it will be integrated in a revision 1.7

Have a nice day,

best regards,

ST NFC/RFID Dynamic tag support

1 reply

Anais GALLIGANI
Visitor II
March 19, 2014
Posted on March 19, 2014 at 17:15

Hello,

Thanks for the notice,

Your request will be taken into account

If you need a draft version with this modification we can send it by email

If not, it will be integrated in a revision 1.7

Have a nice day,

best regards,

ST NFC/RFID Dynamic tag support