M24LR04E-R time to ready from power-up?

  • March 17, 2014
  • 3 replies
  • 1178 views
Posted on March 17, 2014 at 12:24

Hi all,

I'm looking for an indication of worst-case time-to-ready: i.e. from power-up - assume external VCC, not induced power - to fully commandable from I2C. I've searched the datasheet (DocID022208 rev 8) from end to end, and probably missed the obvious, but can't find the number I'm after.

What did I miss? Anyone got a figure for it?

Thanks in advance,

Jon

#m24lr04e-r #por #por #m24lr04 #m24lr #i2c #power-up #i2c-access #time
This topic has been closed for replies.
Best answer by Anais GALLIGANI
Posted on March 31, 2014 at 17:43

Hi Jon,

During power-up, and after PORVCC (#1.5V), a delay of wakeup from the regulator (#40us) is necessary.

Have a nice day,

Best regards,

ST NFC RFID Dynamic e2e support

3 replies

Anais GALLIGANI
Visitor II
March 31, 2014
Posted on March 31, 2014 at 17:43

Hi Jon,

During power-up, and after PORVCC (#1.5V), a delay of wakeup from the regulator (#40us) is necessary.

Have a nice day,

Best regards,

ST NFC RFID Dynamic e2e support

Jon Green
Jon GreenAuthor
Associate II
March 31, 2014
Posted on March 31, 2014 at 17:51

Thanks!

Possibly a good thing to include in the next rev. of the datasheet.

Jon

Anais GALLIGANI
Visitor II
April 1, 2014
Posted on April 01, 2014 at 11:31

yep, thanks,

it will be implemented in the next revision of the datasheet,

Have a nice day,

ST NFC RFID Dynamic tag e2e support