Posted on March 14, 2018 at 16:52Hi, a simple way one could do that would be to put the device in certification mode by sending a downlink with 01010101 to port 224 (start certification mode). Once in certification mode it will do an uplink once every 5 seconds. Sending a downlink containing 07000A to port 224 will put the device in continuous tx mode for 10 seconds (0x0A) using the last frequency and rf power.
Sending a longer command like 07000A84724014 to port 224 will activate 10 second transmission on 868.0 mHz (0x847240) at 20dBm (0x14).
To switch back to your application send 00 to port 224.
Best regards,
RG