Question

STM32WB1MMCH OTP

  • August 26, 2025
  • 1 reply
  • 367 views

STM32WB1MMCH:Can other values be written again after the otp area is written to 0xFF

1 reply

STTwo-32
Technical Moderator
August 26, 2025

Hello @luzuhua and welcome to the ST Community.

According to the RM0473,

« 1 Kbyte (128 double words) OTP (one-time programmable) for user data. The OTP data cannot be erased and can be written only once. If only one bit is at 0 the entire double word (64 bits) cannot be written anymore, even with the value 0x0000 0000 0000 0000. »

Best Regards.

STTwo-32

To give better visibility on the answered topics, please click on Accept as Solution on the reply which solved your issue or answered your question.
luzuhuaAuthor
Associate
August 26, 2025

The first time I write 0x5a to 0x1FFF7008-0x1FFF70F7,and other addr i write 0xFF;The second time,i want to write some value to 0x1FFF70F8-0x0x1FFF73F7,but I found that I cannot write it,May I ask why this is?

STTwo-32
Technical Moderator
September 23, 2025

As i mentioned before, The OTP data cannot be erased and can be written only once. This should be the explication of the behavior you are having here.

Best Regards.