Hello @tabekb ,
First let me welcome you to the STM32 community and thank you for having reported :smiling_face_with_smiling_eyes:
Actually you're right, I was able also to reproduce the same misbehavior from my side.
Actually, an enhancement was done in the latest STM32CubeMX version which is the unavailability of Discontinuous Conversion Mode parameter when Scan Conversion Mode is disabled.
In fact, Discontinuous mode is used only if sequencer is enabled (parameter 'ScanConvMode'). If sequencer is disabled, this parameter is discarded.
I assume this modification is behind the regression.
With this being said, this is reported internally to be reviewed. I'll keep you posted with the updates.
Internal ticket number: 124049 (This is an internal tracking number and is not accessible or usable by customers).
Thanks for your contribution.
Even though this reply doesn’t directly solve the issue, I’m marking it as Best, since it will help clarify the current situation for other customers with the same question. I will post an update here once the issue has been fixed.
Khouloud.